Products Details
General description : CH series intelligent (temperature) display regulator adopts 8-bit single-chip high reliability, a variety of sensors freely input, and it adopts a wide range of switching power supply. The product’s performance indicators, input style, control function and the installation size are fully compatible with the i mported intelligent digital temperature controller. CH series intelligent meters, having the latest fuzzy control and combining with advanced PID adjustment algorithm, precisely control the controlled objects. Size options: Models | External size (W x H x D) | Hole size |
CH102 □□□-□□*□□-□ | 48 x 48 x 110 (mm) | 45 x 45 (mm) |
CH402 □□□-□□*□□-□ | 48 x 96 x 110 (mm) | 45 x 92 (mm) |
CH702 □□□-□□*□□-□ | 72 x 72 x 110 (mm) | 68 x 68 (mm) |
CH902 □□□-□□*□□-□ | 96 x 96 x 110 (mm) | 92 x 92 (mm) |
CH502 □□□-□□*□□-□ | 96 x 48 x 110 (mm) | 92 x 45 (mm) |
Remarks: the symbol ”□” represents what functions you need, please refer to the following explanation. Model explanation: CH□02 □ □ □- □ □*□ □-□ ① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ① Standard sizes: 1(48x48x110mm)、4(48x96x110mm)、7(72x72x110mm)、9(96x96x110mm)、5(96x48x110mm) ② Control style: F: PID action and automatic calculus(reverse action) D: PID action and automatic calculus(positive action) ③ Input style: thermocouple: K, J, R, S, B, E, T, N, W5Re/W26Re, PLII, U, L,thermal resistance Pt100, JPt100 ④ Display range: Input type | Input display range | Code | | Input type | Input display range | Code |
K | 0~200℃ | K 01 | | S | 0~1600℃ | S 01 |
0~400℃ | K 02 | | 0~1769℃ | S 02 |
0~600℃ | K 03 | | B | 400~1800℃ | B 01 |
0~800℃ | K 04 | | 0~1820℃ | B 02 |
0~1200℃ | K 06 | | E | 0~800℃ | E 01 |
J | 0~200℃ | J 01 | | 0~1000℃ | E 02 |
0~400℃ | J 02 | | J | -199.90~+649.0℃ | D 01 |
0~600℃ | J 03 | | -199.90~+200.0℃ | D 02 |
0~800℃ | J 04 | | -100.0~+200.0℃ | D 05 |
0~1200℃ | J 06 | | 0.0~+200.0℃ | D 08 |
R | 0~1600℃ | J 01 | | 0.0~+500.0℃ | D 10 |
⑤ The first control output: (OUT1)(Heating side) M: relay contact output 8: Current output(DC4-20mA) V: voltage pulse output G: Thyristor control tube drive with trigger output T: Thyristor control tube output ⑥ The second control output: (OUT2)(Cooling side)*2 No mark: when the control action is F or C M: relay contact output 8: Current output(DC4-20mA) V: voltage pulse output T: Thyristor control tube output ⑦ First alarm(ALAM1) N: no alarm A: Upper limit deviation alarm B: Lower limit deviation alarm C: Upper and lower limit deviation alarm W: Lower-limit set alarm value H: Upper limit output value alarm ⑧ Second alarm(ALAM)*2(Same content as the frist alarm) J: Lower output value alarm V: Upper set value alarm ⑨ Communication function: N: no communication function 5: RS-485(double cable system) Pvc Slotted Trunking,
Spiral Cable Wrap,
Wing Lock Type Stainless Steel Cable Ties,
Marker Strips For Cable,
End Wire Connectors,
Flat Cable Clip,
Enclosure,
Safety-Type Wire Joints,
Waterproof Quick Corrugated Conduit Connector,
Cable Markers Letters,